Check the battery voltage first. On 24 V, one 25.6 V 200 Ah pack covers everyday loads and two cover full power; on 48 V, one 5 or 10 kWh battery does the job.

The short answer: first check the battery voltage on the inverter label. Many 3.5 KVA inverters run on 24 V, and then you need a 25.6 V LiFePO4 battery: one 25.6 V 200 Ah pack (5.12 kWh) for lights, fans, TV and a fridge, or two in parallel (10.24 kWh) if the inverter will run near full power. If your 3.5 KVA inverter runs on 48 V, one 51.2 V battery of 5 or 10 kWh does the job.

Step 1: Read two figures on the label

  • Output in watts. “3.5 KVA” is apparent power. The real output is usually 3,000 to 3,600 W. Our QD3624MH is rated 3,600 W, the UD3824AM 3,040 W and the JU3824AM8V 3,000 W. Size the battery on the watts.
  • Battery voltage. 24 V needs a 25.6 V lithium battery; 48 V needs a 51.2 V battery. The two are not interchangeable.

Step 2: Check the battery current

At 24 V the same power needs twice the current it needs at 48 V. That is why a 3.5 KVA inverter on 24 V is the case where a single small battery most often runs out of current before it runs out of energy.

Inverter outputOn 24 V (25.6 V battery)On 48 V (51.2 V battery)
1,000 Wabout 41 Aabout 21 A
2,000 Wabout 82 Aabout 41 A
3,000 Wabout 123 Aabout 62 A
3,600 Wabout 148 Aabout 74 A

Battery current = inverter output ÷ battery voltage ÷ about 95% inverter efficiency. Near the end of a discharge the voltage is lower and the current a few percent higher.

Our 25.6 V packs are rated as follows: 100 Ah, 50 A recommended and 100 A maximum; 200 Ah, 100 A recommended and 200 A maximum; 300 Ah, 75 A recommended and 150 A maximum. So one 200 Ah pack supplies about 2.4 kW at its recommended current, and a 3.5 KVA inverter at full power needs two.

Step 3: Choose the hours of backup

Average load1 × 25.6 V 200 Ah
5.12 kWh
2 × 25.6 V 200 Ah
10.24 kWh
2 × 25.6 V 300 Ah
15.36 kWh
300 W12.3 h24.6 h36.9 h
500 W7.4 h14.7 h22.1 h
1,000 W3.7 h7.4 h11.1 h
1,500 W2.5 h4.9 h7.4 h
2,000 W1.8 h3.7 h5.5 h

Using 80% of the rated energy and 90% inverter efficiency.

Our suggestion for a 3.5 KVA inverter

Inverter and useBattery
24 V: lights, fans, TV, Wi-Fi and a fridge (about 300–800 W average)One 25.6 V 200 Ah pack, 5.12 kWh
24 V: near full power for hours, or long power cutsTwo 25.6 V 200 Ah packs in parallel (10.24 kWh), or two 300 Ah packs (15.36 kWh)
48 V: everyday loadsOne 5 kWh unit: 50 A recommended, about 2.4 kW
48 V: full power or longer backupOne 10 kWh unit: 100 A recommended, about 4.9 kW

Mistakes to avoid

  • Buying a 48 V battery for a 24 V inverter, or the other way round. Check the label before ordering.
  • Leaving lead-acid charge settings. On our 25.6 V packs the recommended charge voltage is 29 V and the maximum 29.2 V; the recommended discharge cut-off is 22 V.
  • Too much charge current. Set the inverter’s maximum charge current to the battery’s recommended figure: 100 A for one 200 Ah pack, 75 A for one 300 Ah pack.
  • Too many packs in parallel. Our Bluetooth 25.6 V 100 Ah and 200 Ah packs allow 2 in parallel; the 24V100Ah-S and the 300 Ah pack allow 15. See how to connect batteries in parallel.

Planning to grow past about 10 kWh? A 48 V inverter carries half the current for the same power. See what size battery a 5 KVA inverter needs.

More guides

6 min readHow many kWh of battery does a home need?

A four-step method with worked examples for backup, evening use and air conditioning at night.

Read the guide →
4 min read48 V or high-voltage battery: which one fits?

Inverter match, current and cables, expansion and installation, side by side.

Read the guide →
4 min readHow long will a 10 kWh battery power a home?

A runtime table from 100 W to 5 kW, typical appliance loads and an example evening.

Read the guide →
3 min readHow many Ah is a 16 kWh battery?

Convert kWh to Ah and back at 12, 24 and 48 V, with a table for every common battery size.

Read the guide →
4 min readWhat size lithium battery for a 5 KVA inverter?

Battery current at full load, backup hours for 10–20 kWh, and when to add a second unit.

Read the guide →
5 min readLithium or tubular battery for an inverter?

Usable energy, cycle life, charging, maintenance and space, side by side.

Read the guide →
4 min readHow many solar panels to charge a 10 kWh battery?

The formula, a table for 5–20 kWh at 4–6 sun hours, and the daytime load.

Read the guide →
4 min readWhat size lithium battery for a 10 KVA inverter?

Battery current at 6–11 kW, backup hours for 2 and 3 units, and the settings.

Read the guide →
5 min readHow to connect 48 V lithium batteries in parallel

Matching voltages, busbar wiring, communication and inverter settings.

Read the guide →
5 min readShipping lithium batteries from China: documents and sea freight

UN 3480 by sea, UN38.3 and MSDS, choosing a forwarder, Kenya and Nigeria certificates.

Read the guide →

Need help sizing a system?

Send us the loads, the inverter and the market. We recommend a battery and reply with the datasheet and price.

WhatsApp